Remodelling of mandibular condylar head after fixation of fractures with ultrasound activated resorbable pins: A retrospective case series.
McLeod, Niall Mh ; Saeed, Nadeem R ; Gerber, Barbara ; McLeod, Niall Mh
McLeod, Niall Mh
Saeed, Nadeem R
Gerber, Barbara
McLeod, Niall Mh
Abstract
The aim of this study was to assess whether the resorption of poly-lactic acid pins, used for condylar head fracture fixation, adversely affect remodelling of the condylar head. A retrospective review of patients was performed that underwent ORIF of CHF with ultrasound activated resorbable poly-lactic acid pins and had CT/CBCT scans of the condyle at least 18 months after surgery, at which point the fixation material was expected to be resorbed. We reviewed the size, shape and position of the condylar head and compared this to the normal side and compared this to the results of conservative management and ORIF with titanium screws in the literature. Most patients had condylar heads normally positioned and shaped, with minimal bone changes. The position of the condyle in the fossa, its shape and bone changes compare favourably with previous studies on CHF managed conservatively or with titanium screw fixation. There was no radiographic evidence of the pins after 18 months. In conclusion, ultrasound activated resorbable pins can provide suitable fixation for ORIF of condylar head fractures, avoiding the need for screw removal, and there was no evidence that the resorption process adversely affected the remodelling of the condylar head.
MIDER Authors
Citations
Altmetric:
Date
2023-08-01
Type
Article
Subject
Dentistry
Collections
Citation
J Craniomaxillofac Surg . 2023 Aug 1;S1010-5182(23)00129-4
Journal / Source Title
Journal of Cranio-Maxillofacial Surgery
DOI
10.1016/j.jcms.2023.07.004
PMID
37553264
Publisher
Elsevier