Differences in the product characteristics and clinical use of granulocytes for transfusion: the BEST Collaborative study
Cain, Lorna ; Lafrance, Charles ; Morton, Suzy ; Latour, Catherine ; Girard, Mélissa ; Tiberghien, Pierre ; de la Taille, Virginie ; Datta, Suvro Sankha ; Virk, Mrigender Singh ; Andrews, Jennifer ... show 10 more
Cain, Lorna
Lafrance, Charles
Morton, Suzy
Latour, Catherine
Girard, Mélissa
Tiberghien, Pierre
de la Taille, Virginie
Datta, Suvro Sankha
Virk, Mrigender Singh
Andrews, Jennifer
Abstract
Background: Whether granulocytes for transfusion are beneficial remains uncertain, although some evidence suggests that efficacy may be dose-related. Granulocytes are mostly produced by apheresis procedure, but other means of production are increasingly used.
Methods: Centers that produce and/or use granulocytes were recruited through the BEST Collaborative and completed a detailed survey of granulocyte manufacture, specifications, clinical use, operational considerations, and data collection initiatives.
Results: Fifteen national, regional, and local producers and/or users of granulocytes were included. Granulocytes were produced from apheresis procedure (n = 10), pooled buffy coats (n = 2), single buffy coats (n = 4) or pooling of residual leukocyte units from whole blood processing (n = 1). The mean adult dose of granulocytes reported was 1.6 to 3.7 × 1010 for apheresis, and 1.8 to 2.2 × 1010 for pooled buffy coat granulocytes. For apheresis procedure donations, donor stimulation included steroids and/or granulocyte colony-stimulating factor. Centers providing whole blood-derived granulocytes reported shorter times from request to delivery than those using apheresis procedure products. Indications and product selection criteria were similar. The most frequently reported challenges with granulocytes were donor availability for apheresis procedure (n = 7), short shelf life (n = 5) and lack of evidence of efficacy (n = 5). The cost of one unit of apheresis procedure granulocytes ranged from 568 to 7500 PPP-USD, and for one pooled buffy coat unit was from 2208 to 2822 PPP-USD.
Conclusions: We have highlighted differences in granulocyte production that are relevant for the design and interpretation of much needed international clinical studies.
MIDER Authors
Date
2025-05-15
Type
Article
Subject
Blood transfusion, Leukocytes, Haematology
Collections
Citation
Cain L, Lafrance C, Morton S, Latour C, Girard M, Tiberghien P, de la Taille V, Datta SS, Virk MS, Andrews J, Yahalom V, Pugliese AM, Alba R, Charlewood R, Kirwan S, Yokoyama APH, Kutner JM, Nogues EA, Martinez I Llonch N, Daly J, Irving DO, Schulze TJ, Huisman E, Le Poole K, Vrielink H, Saifee NH, Pagano MB, Stanworth S; Biomedical Excellence for Safer Transfusion Collaborative. Differences in the product characteristics and clinical use of granulocytes for transfusion: The BEST Collaborative study. Transfusion. 2025 Jun;65(6):1111-1123. doi: 10.1111/trf.18263. Epub 2025 May 15.
Journal / Source Title
Transfusion
DOI
10.1111/trf.18263
PMID
40371893
Publisher
American Association Of Blood Banks
Publisher’s URL
https://onlinelibrary.wiley.com/journal/15372995
