Evaluation of a computer-aided detection (CAD)-enhanced 2D synthetic mammogram: Comparison with standard synthetic 2D mammograms and conventional 2D digital mammography
James, Jonathan
James, Jonathan
Abstract
AIM: To evaluate the diagnostic performance of computer-aided detection (CAD)-enhanced synthetic mammograms in comparison with standard synthetic mammograms and full-field digital mammography (FFDM)., MATERIALS AND METHODS: A CAD-enhanced synthetic mammogram, a standard synthetic mammogram, and FFDM were available in 68 breast-screening cases recalled for soft-tissue abnormalities (masses, parenchymal deformities, and asymmetric densities). Two radiologists, blinded to image type and final assessment outcome, retrospectively read oblique and craniocaudal projections for each type of mammogram. The resulting 204 pairs of 2D images were presented in random order and scored on a five-point scale (1, normal to 5, malignant) without access to the Digital breast tomosynthesis (DBT) slices. Receiver operating characteristic (ROC) curve analysis was performed., RESULTS: There were 34 biopsy-proven malignancies and 34 normal/benign cases. Diagnostic accuracy was significantly improved for the CAD-enhanced synthetic mammogram compared to the standard synthetic mammogram (area under the ROC curve AUC]=0.846 and AUC=0.683 respectively, p=0.004) and compared to the conventional 2D FFDM (AUC=0.724, p=0.027). The CAD-enhanced synthetic mammogram had the highest diagnostic accuracy for all soft-tissue abnormalities, and for malignant lesions sensitivity was not affected by tumour size. For all 68 cases, there was an average of 3.2 areas enhanced per image. For the 34 cancer cases, 97.4% of lesions were correctly enhanced, with 2.1 false areas enhanced per image., CONCLUSIONS: CAD enhancement significantly improves performance of synthetic 2D mammograms and also exhibits improved diagnostic accuracy compared to conventional 2D FFDM. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
MIDER Authors
Citations
Altmetric:
Date
2018
Type
Article
Subject
Biopsy, Breast cancer, Digital breast tomosynthesis, Mammography
Collections
Citation
James, J.J., Giannotti, E. and Chen, Y. (2018) 'Evaluation of a computer-aided detection (CAD)-enhanced 2D synthetic mammogram: comparison with standard synthetic 2D mammograms and conventional 2D digital mammography', Clinical Radiology, 73(10), pp. 886-892. doi: 10.1016/j.crad.2018.05.028.
Journal / Source Title
DOI
PMID
Publisher
Elsevier Ltd.