Perforation of the right ventricle during placement of pacing wires is a well-documented complication and can be potentially fatal. Use of temporary pacemaker, helical screw leads and steroids use prior to implant are recognised as risk factors for development of post-permanent pacemaker effusion. We reported an unusual case of pacing wire perforating interventricular septum into the left ventricle that occurred during the implant procedure performed in another institution. After the preoperative work-up and transfer to our tertiary cardiothoracic centre, the patient underwent successful surgical management. In conclusion, early recognition and timely diagnosis using advanced multimodality imaging can guide surgical intervention and prevent unfavourable consequences of device-related complications.